Labratory
Production
Opacity/Haze
Thickness Measurement
Process Control
Analysis
Miscellaneous
The inline opacity meter OPS 400 has a measurement window of up to 60 mm wide. One measurement per second is taken.
The measurable opacity is from transparent to coated black. The output of the measured values are in ln (natural logarithm) – scale 1/x, or opacity (1 / transparency), or transparency value and / or % – scale (0 – 100%). The measured value is displayed numeric and as a graphical trend. The opacity values are stored in the system and can be evaluated per job or order. If maximum and minimum limit values are exceeded 1x warning and 1x alarm limits can be set. And are shown on the monitor and are available as a contact output (alarm). The calibration is performed by means of reference samples or based on the existing laboratory instrument data. The OPS 400 has 4 password protected input levels. Users, machine operators, production managers and service. Contract-related data such as customer, machine, film type and operator are possible. This enables the results of the opacity in regard to the production time, material types, and the production machine is possible. Optionally, the OPS 400 provides the scaled values (and / or raw data) over a 4 – 20 mA or 0-10 Voltage output for controlling or regulation of dosing units and a recycling optimization. Ethernet and USB outputs are available for the measured values as a CSV file via UDP and customer specific data (on request).
| ||||||||||||||||||||
Technical Data
OPS 400integrated
|